THe extended method

EVOSEP+ METHOD

 

Maximum proteome coverage in a single-shot analysis

This EVOSEP+ method is the ideal choice, when maximum proteome coverage in a single experiment is needed, especially when the amount of starting material is limited.

A long gradient with low overhead

The Extended method has a 88 min gradient, equivalent to a throughput of a little more than 15 samples per day, which is possible due to the short 4 min overhead between injections.

It runs with a gradient flow of 220 nl/min and is designed to be used with our EV-1106 column.

It takes advantage of our offset gradient strategy, which results in sharp peaks with highest possible peak capacity.

SIMILAR PERFORMANCE IN TWO DIFFERENT LABORATORIES

Reproducibility is a key aspect in clinical proteomics both in terms of limiting the technical variation between replica injections, but also the inevitable variation between instruments and laboratory procedures.

In a comparative pilot study in two different laboratories, similar proteome coverage is observed with around 35,000 unique peptides corresponding to 5000 proteins from 500 ng peptide load.

The high reproducibility comes from advanced calibration and flow control coupled with continuous self-monitoring and adjustments

A minor difference is observed at the lower loads.

MORE PROTEOME COVERAGE IN A SINGLE EXPERIMENT

Read the entire application note describing the method design, retention time reproducibility and the comparative pilot study.

Data courtesy: Professor Matthias Mann and Johannes Müller, Max-Planck Institute of Biochemistry, Proteomics and Signal Transduction on a Thermo Scientific Orbitrap Exploris 480 MS

explore all available methods with evosep+

Find the method fitting your research need and get inspired with data from Evosep users.

Whisper
80 SPD

EVOSEP+ method

A high-throughput method for scaling single cell analysis.

LEARN MORE

Whisper
40 SPD

EVOSEP+ method

Ultra-sensitive method ideal for single-cell analysis.

LEARN MORE

Whisper
20 SPD

EVOSEP+ method

A longer method for robust and sensitive applications.

LEARN MORE

The High organic method

EVOSEP+ method

This EVOSEP+ method enables small-molecules analysis with significantly more hydrophobic targets.

LEARN MORE

The extended method 

EVOSEP+ method

Maximum proteome coverage in a single-shot analysis with extended gradient duration.

LEARN MORE

DOWNLOAD OUR MATERIAL

brochure
columns and emitters overview
Application Note
A specialized method for maximum proteome coverage with the Extended method

Want to know more?

Our team is ready to help you find the method fitting your research need. Fill out our contact form and we will get back to you as soon as possible