The 300 samples per day method

STANDARD METHOD

Very high peak capacity per minute for high-throughput analysis

The Evosep One is designed for high throughput and robustness, while maintaining sensitivity for proteomics applications.

The 300 SPD method is ideally suited for routine clinical analysis with high run-to-run reproducibility of just 0.24 seconds.

The HIGHEST CHROMATOGRAPHIC PERFORMANCE PER GRADIENT MINUTE

The 300 SPD method provides high peak capacity per minute among our standard methods. Peak capacity is the most common measure of chromatographic performance and is defined as the number of peaks, that can be resolved over a gradient.

For high throughput analysis of complex samples, highest peak capacity in the shortest time is a relevant measure. This is achieved by ultra fast methods employing short columns and high flow rates providing the best separation power per gradient minute made affordable by the low overhead time on the Evosep One.

Importantly, the narrower peaks greatly reduce redundant sampling thus suggesting that the sensitivity of the analysis is boosted by employing the faster standard methods.

High sequencing speed with modern mass spectrometers

The first peptides elute already after 40 seconds, and with a full elution window of 2.3 minutes, the effective gradient elution is 72%. The short overhead time of only 1.6 minutes allows for an ultra high throughput of 300 samples per day.

By utilizing the high sequencing speed on modern mass spectrometers, a high load identifies 3300 unique peptides corresponding to nearly 1000 proteins.

The six standard methods

With the six standard methods, the Evosep One covers a range of use cases from comprehensive proteome analysis with fractionation strategies to ultra high-throughput single-shot analysis. You decide how fast you want to go. 

Standard method

The highest peak capacity per minute with our fastest method for ultra-high throughput analysis.

LEARN MORE

Standard method

Very high peak capacity per minute for high-throughput analysis.

LEARN MORE

Standard method

Excellent sequencing speed with most peptides per minute among our standard methods.

LEARN MORE

Standard method

A great “in-between” method with run-to-run reproducibility of just one second.

LEARN MORE

Standard method

The most popular method with an excellent balance of throughput and depth.

LEARN MORE

Standard method

The longest method with a 44-minute gradient providing the best overall proteome coverage.

LEARN MORE

Explore more

Do you want to know how our users are already taking advantage of the 300 Samples per day method? Find all publications from users and collaboration partners here. Visit our Literature Room for a full overview.

TitleSubjectMaterialYearSummaryInstituteEvosep methodMS instrumentationLearn More
Robust high throughput peptide quantitation using scout triggered MRM on the Triple Quad 7500 system2024, , , ,

Read publication here

Proteomic profiling reveals diagnostic signatures and pathogenic insights in multisystem inflammatory syndrome in children2024

Read publication here

Single cell proteomics by mass spectrometry reveals deep epigenetic insight and new targets of a class specific histone deacetylase inhibitor2024, , , , ,

Read publication here

Rapid and robust PTM peptide mapping for biologics with the Evosep One and the ZenoTOF 76002023, , ,

Read app note here

A standardized separation method with a throughput of 300 samples per day2023This application note describes the 300 samples per day standard method. Get an overview of the method, the chromatographic performance and the results expected from Hela standard injections.

Download application note

Evosep One solves the proteomics dilemma – covering high throughput analysis and proteome depth2023The Evosep One offers a diverse range of applications, utilizing its six standard methods. It caters to various use cases, spanning from comprehensive proteome analysis with fractionation strategies to ultra high-throughput single-shot analysis., , , ,

Download application note

Flexibility, speed, and throughput for high proteome coverage using Zeno SWATH data-independent acquisition (DIA) coupled with the Evosep One system2023, , , , , ,

Read publication here

Rapid and robust PTM peptide mapping for biologics with the Evosep One and the SCIEX ZenoTOF 76002022, ,

Read application note here

On the potential of micro-flow LC-MS/MS in proteomics2022

Read publication here

Targeted assay development for quantifying protein half-life over a range of mouse tissues, , 2019Protein turnover

Watch

High-throughput 4D-Proteomics – Application of dia-PASEF® and the Evosep One for short gradients, 2020diaPASEF app note  , , ,

Download application note

DOWNLOAD OUR MATERIAL

application note
Towards a Standardized Omics Platform with the 300 samples per day method
APPLICATION NOte 
THE PROTEOMICS DILEMMA – HIGH THROUGHPUT ANALYSIS VERSUS PROTEOME DEPTH
BROCHURE
columns and emitters overview

Want to know more?

Our team is ready to help you find the method fitting your research need. Fill out our contact form and we will get back to you as soon as possible

Pop-up Bot
Chat